Hand Fracture System

The Acumed Hand Fracture System is designed to surgically treat various metacarpal and phalangeal fractures, fusions, and osteotomies and includes five solutions in one tray. Versatile screws, customizable plates, and dedicated instrumentation offer a comprehensive system to streamline the surgical experience.

The system features precontoured standard plates, specialty plates, and Hexalobe MultiScrews. Hexalobe Lag Screws and threaded K-wires are also included for less complicated fractures.

The Acumed Small Bone Fixator and Small Bone Distractor provide external fixation options, and can be booked as part of the Hand Fracture system.

For in-depth information, documentation, key publications and specifications, head to the Acumed website here.

To chat with one of our team, or ask us a question, please get in touch. Call us on 1800 225 065 or email info@medopt.com.au.

Key Features

  • Comprehensive System

    The system includes customizable Variable Angle Locking Plates, Small Bone External Fixator, Small Bone Distractor, and partially threaded lag screws

  • Versatile Screw-and-Plate System

    The system was the first in the industry to allow multiple Hand Fracture System screw diameters in every hole of every plate in the system

  • Specialized Plates

    Rolando Fracture Hook, Metacarpal Neck Fracture, Avulsion Hook, Curved Medial/Lateral and Rotational Correction plates

  • Specialized Instruments

    Specialized instruments in the system include an osteotomy cutting guide, the SaveLoc compression sleeve, unique clamps and forceps, and a plate cutter

Video Tour

This animated overview of the Hand Fracture System illustrates how the system is designed to surgically treat various metacarpal and phalangeal fractures, fusions, and osteotomies. Precontoured standard plates, specialty plates, Hexalobe MultiScrews, Hexalobe Lag Screws, and external fixation devices provide multiple surgical options for the hand.

The Hand Fracture System Plate Family

Acumed offers the all-in-one Hand Fracture System for management of fractures, fusions, and osteotomies for distal, middle, and proximal phalanges and metacarpals. This low-profile, multi-plate system features precontoured standard and specialty plates, Hexalobe MultiScrews, Hexalobe Lag Screws, pins, and external fixation devices, which are all included to streamline the surgical experience. Acumed’s Hexalobe MultiScrew technology allows for the same screw to act as a nonlocking and locking variable angle screw, eliminating the need for traditional locking and nonlocking screws. Innovative instrumentation is provided for provisional fixation, along with a rounded-edge plate cutter designed to minimize soft tissue irritation. This comprehensive system contains multiple surgical treatment options for the hand in one convenient tray.

The 0.8 mm Avulsion Hook Plate is designed to provide more stability than a K-wire when a fragment is too small for a single lag screw. The prongs in the 0.8 mm Avulsion Hook Plate are used to support an avulsion fragment when the avulsed fragment is too small for a lag screw and more stability is desired than pinning with K-wires alone can provide. This can often occur at the insertion of the collateral ligaments in the proximal phalanges.

The 1.3 mm Rolando Fracture Hook Plate is designed for a three-part fracture pattern at the base of the first metacarpal. The prongs on the proximal end of the 1.3 mm Rolando Fracture Hook Plate should contact the dorsal surface of the abductor pollicis longus (APL) tendon and support any comminution of the base of the first metacarpal. These prongs are not intended to compress the APL tendon down to the bone and a gap may be visible between the plate prongs and the bone on X-ray.

The 1.3 mm Metacarpal Neck Plate is designed to provide fixation for metacarpal neck fractures. The plate is positioned dorso-laterally. If a medial placement is preferred, the plate opposite to the hand may be used, i.e., the right metacarpal neck plate on the left hand.

The 1.3 mm Rotational Correction Plate is designed to be used with an osteotomy for correcting rotational malunions. A Rotational Osteotomy Cutting Guide is included in the Hand Fracture System that is designed to facilitate precise placement and orientation of cuts for rotational osteotomies of the metacarpals.

The 0.8 mm Offset Plate is designed to provide fixation for diaphyseal fractures. The 0.8 mm Curved Medial/Lateral Plate is designed for diaphyseal fractures when a medial or lateral approach is preferred. Offset Plates and Curved Medial/Lateral Plates, like all of the Hand Fracture System plates, are low profile, designed to reduce soft tissue irritation. All plates may be bent to fit and cut to length to better fit specific patient anatomy.

Standard plates include the Offset Plate, 6- and 10-Hole Straight Plates, and T-Plates. These plates come in 0.8 mm and 1.3 mm thicknesses, except the Offset Plate which is 0.8 mm only. Plates may be bent to fit and cut to length to better fit individual patient anatomy. Custom plate cutters included in the Hand Fracture System tray are designed to leave a rounded edge, designed to reduce soft tissue irritation. Plate cutters may be used with any Hand Fracture System plate except the Avulsion Plate.

Hexalobe MultiScrew and Lag Screw Technology

1. Designed to be used with any plate in the Hand Fracture System, 1.5 mm and 2.3 mm Hexalobe MultiScrews act as nonlocking screws when inserted into unthreaded slots and locking variable angle screws when inserted into threaded holes. The Hexalobe MultiScrew design allows for angles of up to 15 degrees in any direction for a total of 30 degrees. The SaveLock Compression Sleeve is designed to aid with plate reduction.

2. Designed to be used as an adjunct to plate fixation or for fractures which can be treated with lag screws alone, the 1.5 mm and 2.3 mm Hexalobe Lag Screws do not require overdrilling of the near cortex. Hexalobe Lag Screws are intended to be used independently of plates or through slotted plate holes only. When using lag screws as nonlocking screws in plates, ensure the screw engages the far cortex since lag screws are partially threaded and unable only partially to engage the near cortex. It is recommended to not use more than two lag screws per plate if they are being used as nonlocking screws.

Numerous Possible Plate Configurations

The Acumed Hand Fracture System offers plates in 0.8 mm and 1.3 mm thicknesses. Plates can be cut to length and bent to fit to better treat a wide variety of fracture patterns.

Multiple Choices, Multiple Options

Custom plate cutters are included in the Acumed Hand Fracture System, and are designed to create a smooth rounded edge on all plates except the Avulsion Plate. These plates feature divots that aid in provisional fixation when used with the system’s forceps and clamps.

Get in touch with our Orthopaedics team

=